Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/39731
Tipo: Tese
Título: Determinação de contaminantes emergentes e hidrocarbonetos policíclicos aromáticos: dispositivos de amostragem passiva em água
Título(s) alternativo(s): Determination of emerging contaminants and polycyclic aromatic hydrocarbons: passive sampling devices in water
Autor(es): Martins, Adrielle Beatrice do Ó
Primeiro Orientador: Barbosa, Ana Cecília Rizzatti Albergaria
Segundo Orientador: Combi, Tatiane
metadata.dc.contributor.referee1: Barbosa, Ana Cecília Rizzatti Albergaria
metadata.dc.contributor.referee2: Combi, Tatiane
metadata.dc.contributor.referee3: Rocha, Gisele Olímpio da
metadata.dc.contributor.referee4: Machado, Maria Elisabete
metadata.dc.contributor.referee5: Lourenço, Rafael André
Resumo: Ambientes costeiros localizados próximo a centros urbanos e industriais são usualmente contaminados por compostos de origem antropogênica, como os hidrocarbonetos policíclicos aromáticos (HPAs) e os contaminantes emergentes (CECs). Nos sistemas marinhos, as concentrações desses compostos geralmente são baixas devido a processos como diluição e degradação. No entanto, a presença desses contaminantes é preocupante mesmo em concentrações relativamente baixas, conforme evidenciado pela detecção de efeitos biológicos em níveis ambientais. Dentre as diferentes formas para monitoramento destes ambientes costeiros, dispositivos de amostragem passiva (passive sampler devices, PSDs) têm sido amplamente estudados para avaliar a presença de compostos orgânicos antropogênicos em ambientes aquáticos. Com isto, diversos modelos estão sendo testados, como o caso das tiras de silicone da J-Flex®, utilizadas neste trabalho. O presente estudo avaliou a aplicabilidade deste material para monitoramento simultâneo de compostos emergentes e históricos em coluna d’água. Para isso, foi desenvolvido um método analítico para uso dos PSDs em estudos de contaminação por CECs, empregando-o posteriormente em estudos ambientais. Foram realizados testes de recuperação dos analitos, procedimentos de validação do método analítico e experimentos baseados no método co-solvente para estimar o coeficiente de partição dos analitos (KPW) de interesse. Este estudo determinou os KPW para seis fragrâncias (tetrametil acetiloctahidronaftaleno - OTNE, fantolida - AHMI, tonalide - AHTN, celestolide - DPMI, galaxolide - HHCB, traseolida - ATII) e oito filtros UV (benzofenona-3 – BP3, avobenzona - ABZ, octocrileno - OCT, 2-hidroxibenzofenona – 2OHBP, 4-metilbenzilideno cânfora – 4MBC, homosalato - HMS, salicilato de 2-etil-hexila – EHS e metoxicinamato de 2-etil-hexila – EHMC). Os valores de log KPW obtidos variaram de 4,46 (BP3) a 6,47 (EHMC). Após aplicação em campo, a adequação da borracha de silicone como PSD foi comprovada, observando-se o alcance mais lento e mais preciso do equilíbrio. Após a validação de todas as etapas do método analítico, os PSDs foram expostos em uma região da Baía de Todos os Santos (Bahia – Brasil), região turística, com forte presença de atividades aquáticas, náuticas e incluída em parque ambiental marinho durante um ano. As concentrações livremente dissolvidas variaram de 1,16 (DPMI) a 303 (HHCB) pg L-1 para as fragrâncias e de 3.55 (2OHBP) a 4051 (HMS) pg L-1 para os filtros UV. Para contaminantes legados, a soma da concentração livremente dissolvida variou de 9,39 a 1197 pg L-1 para PCBs, de <MDL (limite de detecção do método) a 7,05 pg L-1 para pesticidas organoclorados e de 3.759 a 21.975 pg L-1 para HPAs. De acordo com as razões diagnósticas os HPAs apontam origem em fontes mistas (pirolíticas e petrogênicas). Foi realizada uma avaliação de risco ambiental para as substâncias químicas para as quais havia dados ecotoxicológicos disponíveis, indicando que os filtros UV e os contaminantes históricos representam o maior risco potencial para os organismos. De forma complementar, um levantamento bibliográfico através de uma revisão sistemática foi realizado a fim de investigar as respostas dos biomarcadores em organismos bivalves aos CECs, visto que na literatura há uma forte comparação entre a avaliação de contaminação através dos amostradores passivos e esta classe de organismos. Em geral, o estudo revelou que os efeitos dos contaminantes nestes organismos ainda não é claro, porém há alteração nas atividades e níveis da maiores os biomarcadores na presença destes compostos.
Abstract: Coastal environments located near urban and industrial centers are usually contaminated by compounds of anthropogenic origin, such as polycyclic aromatic hydrocarbons (PAHs) and emerging contaminants (CECs). In marine systems, the concentrations of these compounds are generally low due to processes such as dilution and degradation. However, the presence of these contaminants is of concern even at relatively low concentrations, as evidenced by the detection of biological effects at environmental levels. Among the different ways of monitoring these coastal environments, passive sampler devices (PSDs) have been widely studied to assess the presence of anthropogenic organic compounds in aquatic environments. Various models are being tested, such as the J-Flex® silicone strips used in this study. This study evaluated the applicability of this material for simultaneous monitoring of emerging and legacy compounds in the water column. To this end, an analytical method was developed for the use of PSDs in CEC contamination studies, and subsequently used in environmental studies. Analyte recovery tests, analytical method validation procedures and experiments based on the co-solvent method were carried out to estimate the analyte partition coefficient (KPW) of interest. This study determined the KPW for six fragrances (tetramethyl acetyloctahydronaphthalene - OTNE, phantolide - AHMI, tonalide - AHTN, celestolide - DPMI, galaxolide - HHCB, traseolide - ATII) and eight UV filters (benzophenone-3 - BP3, avobenzone - ABZ, octocrylene - OCT, 2-hydroxybenzophenone - 2OHBP, 4-methylbenzylidene camphor - 4MBC, homosalate - HMS, 2-ethylhexyl salicylate - EHS and 2-ethylhexyl methoxycinnamate - EHMC). The log KPW values obtained ranged from 4.46 (BP3) to 6.47 (EHMC). After a field test, the suitability of silicone rubber as a PSD was proven, with slower and more accurate balance being achieved. After all the stages of the analytical method had been validated, the PSDs were exposed in a region of Todos os Santos Bay (Bahia - Brazil), a tourist region with a strong presence of aquatic and nautical activities and included in a marine environmental park during one year. Freely dissolved concentrations ranged from 1.16 (DPMI) to 303 (HHCB) pg L-1 for fragrances and from 3.55 (2OHBP) to 4051 (HMS) pg L-1 for UV filters. For legacy contaminants, the sum of the freely dissolved concentration ranged from 9.39 to 1197 pg L-1 for PCBs, from <MDL (method detection limit) to 7.05 pg L-1 for organochlorine pesticides and from 3,759 to 21,975 pg L-1 for PAHs. According to the diagnostic ratios, the PAHs originate from mixed sources (pyrolytic and petrogenic). An environmental risk assessment was carried out for the chemical substances for which ecotoxicological data was available, indicating that UV filters and legacy contaminants represent the greatest potential risk to organisms. To complement this, a bibliographic survey using meta-analysis was carried out in order to investigate the responses of biomarkers in bivalve organisms to CECs, since in the literature there is a strong comparison between the assessment of contamination through passive samplers and this class of organisms. In general, the study revealed that the effects of the contaminants on these organisms is still unclear, but there are changes in the activities and levels of the major biomarkers in the presence of these compounds.
Palavras-chave: Contaminantes orgânicos
Borracha de silicone
HPAs
Produtos de cuidado pessoal
CNPq: CNPQ::CIENCIAS EXATAS E DA TERRA::OCEANOGRAFIA::OCEANOGRAFIA QUIMICA::PROPRIEDADES QUIMICAS DA AGUA DO MAR
Idioma: por
País: Brasil
Editora / Evento / Instituição: Universidade Federal da Bahia
Sigla da Instituição: UFBA
metadata.dc.publisher.department: Escola Politécnica
metadata.dc.publisher.program: Centro Interdisciplinar de Energia e Ambiente (CIEnAm-PG) 
Tipo de Acesso: Acesso Aberto
URI: https://repositorio.ufba.br/handle/ri/39731
Data do documento: 5-Jul-2024
Aparece nas coleções:Tese (PPGEnAm)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
TESE_ADRIELLE MARTINS_versão corrigida.pdf3,65 MBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.